Power Utility Test
Products listed on this page are only a small selection of what is available from our suppliers. Please contact us for information on other models.
Hydran M2

Fault Gas & Moisture Monitor.
• provides early warning of transformer fault conditions that could result in equipment failures or unscheduled outages
• measures composite value of gases generated by faults and oil moisture level
.
TMC 4001

• measures cell voltages
• measures terminal voltage
• masures string current
• various models up to 127 channels
.
AEMC 6250

.
Baur Frida VLF

.
Baur IRG 2000
.
Baur IRG3000

The windows-based software allows every user easy and fast operation of the system. Up to three cable fault location methods can be displayed at the same time on the TFT-LCD display. The high resolution and zoom function enable accurate pre-location of cable faults. The design of IRG 3000 has set new international standards in automatic cable fault location.
.
Baur PHG 70

• cable testing using the VLF (Very Low Frequency) principal
• system can be expanded to incorporate TD-Dissipation Factor and PD-Partial Discharge measurements.
.
Baur Shirla
The special measuring bridge is performing the measurements according to Murray and Glaser. With the integrated high voltage DC source, shirla allows prelocation of low resistive as well as high resistive cable faults. The measuring principle enables prelocation of faults especially at unshielded control- and lighting cables as well as cable sheath!
Analyses are done automatically and the results are displayed digitally.
For cable fault pin pointing according to the step voltage method, a defined DC pulse pattern is applied and the step voltage can be picked up by using the KMF1 or UL30 receiver set.
.
Baur STG 600

.
Baur SYSCOMPACT 3000

The SYSCOMPACT 3000 is used in low and medium voltage networks, for locating faults on cables up to and over 200 km in length. The integration of the latest fault prelocation methods SIM-MIM and impulse current method allows the precise location of high and low-resistance as well as intermittent faults using the IRG 3000 echometer. The IRG 3000 computer-supported impulse-reflection measuring system permits automated cable fault location. For the first time, the software supports a standardised computer link in the users language.
.
Baur UL 30

With its integrated acoustic propagation time measurement the UL 30 displays the distance to the fault in metres and indicates the position if the fault is reached. The special feature of UL 30 is the calculation of the fault distance between two manholes.
In combination with the audio frequency transmitter (TG) and detecting rod (SP 30) the UL 30 is used for route tracing and depth evaluation of electric lines and cables.
.
Baur VIOLA VLF

Two-part design, portable testing equipment.
.
High Voltage Diagnostics Inc HVA 30

.
High Voltage Diagnostics Inc HVA 60

.
Hioki 3454-11

• 250/500/1000VDC voltage ranges
• 4000MΞ© measurement range
• low resistance measurement
• comparator mode
• live wire warning
.
Hioki 3455
.
ISA BTS 200
• Constant current or constant power discharge testing of battery banks
• 24 to 240 battery bank voltage
• discharge currents up to 130 amps
• extra load units can be added for up to 1300 amp discharge current.
.
ISA CBA 1000
This circuit breaker timing test equipment is a reliable and very accurate operating device for the maintenance and commissioning of circuit breakers in medium and high voltage substation. It can perform static and dynamic contact resistance measurement and its an accurate timing speed and motion analyzer.
Circuit Breaker timing test set suitable for EHV, HV and MV circuit breakers
Optional 200 A microhmmeter - static and dynamic contact resistance measurement
6 main and 6 resistive contact inputs
Up to 4 trip/close coils control
7 analog inputs
4 auxiliary timing contact
Circuit Breaker test with two ends connected to ground (BSG option)
Cross trigger for the synchronization of up to 4 CBA 1000
Stand alone functionality - no PC connection is required
Analysis and result evaluation directly on the display
Internal memory for up to 250 test results and 64 pre-defined test plans
USB and RS232 port
.
ISA CBA 2000
This circuit breaker diagnostic system is designed to deliver the highest accuracy while testing circuit breaker. It can perform static and dynamic contact resistance measurement and its a precise timing speed and motion analyzer. Circuit breaker timing test set CBA 2000 is worldwide acknowledged as the perfect solution when a complete and reliable diagnostics has to be performed on circuit breakers.
Designed for the complete test of all circuit breakers
Built-in 200 A microhmmeter - static and dynamic contact resistance measurement
12 auxiliary timing inputs
Up to 4 trip/close coils control
Up to 18 main and 18 resistive contact inputs
Circuit Breaker test with both sides connected to ground (BSG option)
Digital transducer option for motion analysis
Minimum Trip Voltage Test (optional)
Stand alone functionality - no PC connection is required
Analysis and result evaluation directly on the display
Internal memory for up to 500 test results and 64 pre-defined test plans
.
ISA T2000
Multi function system for testing: current, voltage and power transformers
Current transformer excitation, ratio and polarity test set
Primary injection testing capabilities
3000 V AC high-pot test
Generates up to 800 A (option up to 4000A with high current booster)
Microhmmeter function (option): up to 400A DC
RS232 interface for pc connection
Test results and settings are saved into local memory
Compact and lightweight: 26 kg
.
ISA T3000
Multi function primary test system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers
Primary injection testing capabilities
3000 V AC high-pot test
Generates up to 800 A (option up to 4000A with high current booster)
Microhmmeter function (option): up to 400A DC
RS232 interface for pc connection
Possibility to store test results in T3000 local memory (up to 500 results)
Compact and lightweight: 29 kg
.
Megabras MD5060 x

Microprocessor controlled
Insulation test up to 5 TΩ
Test voltages: 0,5 kV to 5 kV in 100 V steps
Short circuit current: 1,5 ± 0,5 mA
Auto-range
Automatic measurement of Dielectric Absorption Index (DAI)
Automatic measurement of Polarization Index (PI)
Step Voltage Test (SVT)
Built-in memory for up to 4000 measured values
Built-in printer
Real-time clock and calendar
Programmable Pass-fail test
.
Megabras Mi10KVe
Insulation test up to 2.000.000MΩ
4 test voltages: 1 kV - 2 kV - 5 kV - 10 kV
Guard terminal
Rechargeable battery
Multiple scales for precision improvement
Portable, accurate & rugged
IP-54 protection
CE mark
.
Megabras Mi20KVe
Insulation test up to 4.000.000MΩ
4 test voltages: 5 kV - 10 kV - 15 kV - 20 kV
Guard terminal
Rechargeable battery
Multiple scales for precision improvement
Portable, accurate & rugged
IP-54 protection
CE mark
.
Megabras MPK204
• Microprocessor controlled
• Alphanumerical display
• Resolution down to: 0,1μΩ
• Resistance reading up to: 200Ω
• Up to 200 A test current
• Kelvin-type (4 - wires) measurement
• Powered by internal battery or mains supply
• Direct reading (up to 41/2 digits)
• Overheating protection
• Serial data output (RS-232)
• Lightweight (16 kg)
.
Megabras MPK253

• Very low resistance measurement
• 1μΩ resolution
• 41/2 digits reading
• Alphanumerical display
• Heavy duty equipment
• Rechargeable battery
• Up to 10 A test current
• 0,25% basic accuracy
• Offset free reading
• RS-232 data output
• IP-54 protection
• CE mark
.
Phenix Technologies PATTR-03

• turns ratio measurement
• excitation current measurement
• measurement of phase angle
• on board printer.
.
Red Phase 590

• Insitu and static testing of CT's (current transformers)
.
Schonstedt Tracemaster II
• 4 active transmitter frequencies
• One button depth measurement
• passive 50Hz detection
• digital readout of signal strength
• conductively or inductively couple the transmitter to the cable
• sonde options for non metallic pipe
.
Schonstedt XTpC
• Compact retractable receiver
• small lightweight transmitter
• one button depth measurement
• passive 50 Hz detection
• automatic gain control
• conductively or inductively couple to cable
• sonde options for non metallic pipe
.
T&R DSM 200

• 0-10A and 0-200A DC test current
• 0.1μΩ resolution
• mV, A, and μΩ displayed simultaneously
• Direct Ohms reading at any current
• Large back-lit liquid crystal display
• Thermal and over-current protection
• Compact and portable
• Isolated RS232 interface for printer or PC
• Triple supply voltage
• Microprocessor controlled
.